Brocade Fabric OS v6.4.3f Release Notes v1.0

Close with Code Change in Fabric OS v6.4.2a
Fabric OS v6.4.3f Release Notes v1.0 Page 83 of 149
Defect ID: DEFECT000328463
Technical Severity: Medium
Summary: Switch View: Port status not getting updated for FAULTY blades
Symptom: Port status not getting updated for FAULTY blade in switch view
Feature: WebMgmt
Function: Switch Explorer/Switch View
Probability: Medium
Found in Release: FOS7.0.0
Defect ID: DEFECT000331430
Technical Severity: Medium
Summary: SNMP: SW-MIB: As per RFC 2578, swFwClassesAreas should not have variables with
hyphen character
Symptom: The user will find SwFwClassesAreas defined with illegal hyphen character which is not
compliant to the RFC
Feature: Mgmt Embedded - SNMP
Function: Other
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000334074
Technical Severity: Medium
Summary: Port throughput graph for an E port trunk group is not showing any data on some slot
position.
Symptom: Customer sees no throughput though there is traffic running
Feature: Port Statistics
Function: Other
Probability: Low
Found in Release: FOS7.0.0
Defect ID: DEFECT000335240
Technical Severity: Medium
Summary: Added a new configurable parameter to optimize i2c driver access
Symptom: Customer may observe Temporary laser fault with SFP, or other I2c access retries during
heavy load. Added configurable parameter to enhance i2c access for site with high CPU
load: the configurechassis CLI command,system attributes / i2cTurboCnfg parameter has
following options:
0 = disable i2cturbo
1 = enable i2cTurbo for SFPs only
2 = enable i2cTurbo for all.
By default, it's set to 0 on FOS v6.3.x/6.4.x and 1 for FOS v7.0.0
Feature: System Controls/EM
Function: PCI/I2C
Probability: Low
Found in Release: FOS7.0.0
Where Else Fixed: FOS6.3.2 c