DCFM Professional Plus User Manual (53-1001774-01, June 2010)

38 DCFM Professional Plus User Manual
53-1001774-01
2
For M-EOS devices, the Management application accepts IP addresses in IPv4 and IPv6
formats. The IPv4 format is valid when the Operating System has IPv4 mode only or dual stack
mode. The IPv6 format is valid when the Operating System has IPv6 mode only or dual stack
mode.
If the firmware version is between M-EOS 9.6.X and 9.9.2, only the domain ID, WWN, and
topology are obtained for fabric members. To manage other fabric members, you must enter
specific IP addresses in the Discover Setup dialog box.
For Admin Domain (AD) discovery, Fabric OS switch must have Physical AD visibility.
For Virtual Fabric discovery device requirements, refer to “Virtual Fabrics requirements” on
page 554.
To discover a Virtual Fabric device, you must have the following permissions:
Switch user account with Chassis Admin role permission on the physical chassis.
Switch and SNMP v3 user account with access rights to all logical switches (all Fabric IDs
(1 - 128).
For information about configuring permissions on a Fabric OS device, refer to the
Fabric OS Administrator’s Guide.:
5. (Fabric OS devices only) Enter the user ID and password for the switch in the User ID and
Password fields.
6. Click the SNMP tab (Figure 20).
FIGURE 20 Address Properties dialog box (SNMP - v1 tab)
7. Enter the duration (in seconds) after which the application times out in the Time-out (sec) field.
8. Enter the number of times to retry the process in the Retries field.
9. Select the SNMP version from the SNMP Version list.
If you selected v1, continue with step 10.
If you select v3, the SNMP tab displays the v3 required parameters. Go to step 14.
To discover a Fabric OS device (not virtual fabric-capable), you must provide the existing
SNMP v3 username present in the switch.
To discover a Virtual Fabric device, you must configure SNMP v3 and your SNMP v3 user
account must be defined as a Fabric OS switch user.