Comware CLI Commands in Provision Software 2013/06

display interface
Related ProVisionComware
show interface <port>display interface
Displays current state about a specified port and related information. If no port number is specified,
information is displayed for all ports.
HP Switch# display interface a1
A1 current state: UP
IP Packet Frame Type: n/a, Hardware Address: 001560-f9b0ff
Description: A1 interface
Loopback is n/a
Media type is twisted Pair
Port hardware type is 100/1000T
1000Mbps-speed mode, full-duplex mode
Link speed type is autonegotiation, link duplex type is
autonegotiation
Flow-control is not enabled
The Maximum Frame Length is 9216
Broadcast MAX-ratio: n/a
Unicast MAX-ratio: n/a
Multicast MAX-ratio: n/a
Jumbo frame: [ see "show jumbos"]
PVID : 1
Mdi type: MDIX
Link delay is n/a
Port link-type: n/a
Tagged VLAN ID : none
Untagged VLAN ID : 1
Port priority: No-override
Last clearing of counters: n/a
Peak value of input: n/a
Peak value of output: n/a
Last 300 seconds input: 0 packets/sec 128846 bytes/sec 0%
Last 300 seconds output: 0 packets/sec 65444 bytes/sec 0%
Input (total): 0 packets, 26 bytes
3 unicasts, 2 broadcasts, 21 multicasts, 0 pauses
Input (normal): 0 packets, 26 bytes
3 unicasts, 2 broadcasts, 21 multicasts, 0 pauses
Input: 0 input errors, 0 runts, 0 giants, n/a throttles
0 CRC, 0 frame, n/a overruns, n/a aborts
n/a ignored, n/a parity errors
Output (total): 0 packets, 24 bytes
0 unicasts, 4 broadcasts, 20 multicasts, 0 pauses
Output (normal): 0 packets, 24 bytes
0 unicasts, 4 broadcasts, 20 multicasts, 0 pauses
Output: 0 output errors, n/a underruns, n/a buffer failures
n/a aborts, 0 deferred, 0 collisions, 0 late collisions
n/a lost carrier, n/a no carrier
Example of Related ProVision Software Command Output.
HP Switch# show interfaces brief
Status and Counters - Port Status
| Intrusion MDI Flow Bcast
Port Type | Alert Enabled Status Mode Mode Ctrl Limit
----- ---------+ --------- ------- ------ ---- ---- ---- -----
B1 100/1000T | No Yes Down Auto-10-100 Auto off 0
B2 100/1000T | No Yes Down 1000FDx Auto off 0
B3 100/1000T | No Yes Down 1000FDx Auto off 0
102 Display Commands