Comware CLI Commands in Provision Software 2013/06
display transceiver diagnosis interface
Related ProVisionComware
show interface transceiver [<port> | detail ]display transceiver diagnosis interface
Displays the currently measured value of digital diagnosis parameters of H3C customized
anti-spoofing pluggable optical transceivers.
HP Switch(config)# display transceiver diagnosis interface g1
G1 transceiver diagnostic information:
Current diagnostic parameters:
Temp.(C) Voltage(V) Bias(mA) RX power(dBM) TX power(dBM)
25.000 0.0000 7.864 -inf -2.350
HP Switch(config)# display transceiver diagnosis interface g4
G4 transceiver diagnostic information:
Error: The transceiver does not support this function.
Field Descriptions
transceiver diagnostic information: Digital diagnosis information of the transceiver plugged in the
interface.
Current diagnostic parameters: Current diagnostic parameters.
Temp.(°C): Digital diagnosis parameter-temperature, in °C, with the precision to 1°C.
Voltage(V): Digital diagnosis parameter-voltage, in V, with the precision to 0.01 V.
Bias(mA): Digital diagnosis parameter-bias current, in mA, with the precision to 0.01 mA.
RX power(dBM): Digital diagnosis parameter-RX power, in dBM, with the precision to 0.01 dBM.
TX power(dBM): Digital diagnosis parameter-TX power, in dBM, with the precision to 0.01 dBM.
Operating Notes
For more information on transceivers, see the "Troubleshooting" chapter in the latest Management
and Configuration Guide for your switch.
Example of Related ProVision Software Command Output.
HP Switch(config)# sh int transceiver 24 detail
Transceiver in 24
Interface Index : 124
Type : SFP+LR
Model : J9151A
Connector Type : LC
Wavelength : 1310nm
Transfer Distance : 10.0km (9um),
Diagnostic Support : DOM
Serial Number : CN847GV009
Status
Temperature : 35.148C
Voltage : 3.2348V
Tx Bias : 41.952mA
Tx Power : 0.4047mW, -3.929dBm
Rx Power : 0.0006mW, -32.218dBm
Recent Alarms :
Rx power low alarm
Rx power low warning
Recent Errors :
306 Display Commands