FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes, Version B.11.23.03
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes
Known Problems and Workarounds and Recommendations
Chapter 1
6
Known Problems and Workarounds and Recommendations
Connecting to an FL Port Through a Hub
Recommendation
In configurations where HP Fibre Channel HBAs are connected to an FL port through a hub, the following
are recommended:
• FL ports that are connected to a hub should be locked into loop-only mode wherever possible. With HP
StorageWorks SAN 2/8, SAN 2/16, SAN 2/32 or Core 2/64 switches this can be done using the
portCfgLport command, which is documented in the switch manual.
• Always have at least one non-FL port connected to the hub when there is an FL port connected to the hub.
• Plug the FL port last into the hub.
• Do not reboot all hosts connected to the hub at the same time.
• Do not reset all HBA ports connected to the hub at the same time.
• HBA ports should not be connected to adjacent ports on a hub wherever possible.
8606391884 Incorrect information in the fcdlist man page
8606392547 set_int_delay command does not display any message when command is successful
8606392748 fcmsutil: does not check to discover if too many parameters have been given
8606395620 The vgcfgbackup command hangs with the fcd driver
8606395543 A6826A HBA is not coming online when connected to an 8 port Brocade switch
8606369480 The fcd driver is not seeing devices through the Cisco MDS 9000 family of switches
8606394349 SAN configuration changes might lead to boot failure from devices seen by the fcd driver.
Table 1-2 HP-UX 11i v2 March 2005 Fixes (Continued)
SR Number Description