A6826A Fibre Channel Mass Storage Adapter Installation Guide, February 2007

Fibre Channel Adapter Installation for HP-UX
Interpreting Legacy Hardware Paths (HP-UX 11i v1 and 11i v2)
Chapter 1
13
3. HP Fibre Channel Mass Storage installation is verified if the ioscan output lists all mass storage devices
attached to the adapter. If any attached devices are not listed or appear as UNCLAIMED, see the
Troubleshooting and Maintenance chapter of the HP Fibre Channel Adapters Support Guide.
Interpreting Legacy Hardware Paths (HP-UX 11i v1 and 11i v2)
Example 1-1, Example 1-2 and Example 1-3 illustrate the Fibre Channel hardware path format:
Example 1-1 Hardware Path for a Public Loop Device
Example 1-2 Hardware Path for a Direct Fabric Attach Device
Example 1-3 Hardware Path for a Private Loop Device
Table 1-3 describes each field in the hardware path.
Table 1-3 Hardware Path Field Descriptions
Field Value
Fibre Channel Topology of HBA
Fabric Topologies Private Loop
Adapter The hardware path of the Fibre Channel adapter through which the Logical Unit Number
(LUN) is seen. For multiport adapters, this field describes a specific port on the adapter.
Domain Dependent on the
Fibre Channel
topology of the HBA.
Typically the Domain ID of the
switch to which the target device is
attached, taken from the most
significant byte of the N_Port ID of
the target device.
8
HP-UX uses a Domain ID of 8 to
indicate private loops. Fibre
Channel switches seen by
HP-UX hosts cannot be
configured with domain ID of 8.
Adapter Area Port Bus Target LUNDomain
0/1/2/0.1.19.255.15.4.0
Adapter Area Port Bus Target LUNDomain
0/1/2/0.1.19.255.0.0.0
Adapter Area Port Bus Target LUNDomain
0/1/2/0.8.0.255.0.1.0