FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Software Version B.11.23.03 Manufacturing Part Number: J6374-90022 E0305 Printed in the US © Copyright 2005 Hewlett Packard Development Company L.P.
Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes What’s in This Release Note 1 FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes What’s in This Release Note This release note contains information pertaining to the 11.23.03 version of the FibrChanl-01 (fcd) Fibre Channel Mass Storage driver provided with HP-UX 11i v1 and 11i v2.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Compatibility Information and Installation Requirements Compatibility Information and Installation Requirements Software Requirements The following software (or later versions) must be installed before installing the FibrChanl-01 (fcd) driver, version B.11.23.03 into a system: • FibrChanl-00 (td) version B.11.23.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Driver Versions Driver Versions The driver versions for each release of the FibrChanl-01 (fcd) driver: Table 1-1 FibrChanl-01 (fcd) Driver Version History Release Revision AR0903 AR1203 AR0304 B.11.23.01 (64-bit) AR0604 HP-UX 11i v2 September 2004 B.11.23.02 (64-bit) March 2005 B.11.23.03 (64-bit) Known Problems Fixed in This Version The following defect fixes were included in the 11.23.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Known Problems and Workarounds and Recommendations Table 1-2 HP-UX 11i v2 March 2005 Fixes (Continued) SR Number Description 8606391884 Incorrect information in the fcdlist man page 8606392547 set_int_delay command does not display any message when command is successful 8606392748 fcmsutil: does not check to discover if too many parameters have been given 8606395620 The vgcfgbackup command hangs with the fcd driv
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Known Problems and Workarounds and Recommendations Using ioscan with krm Not Running A general issue when using ioscan when krm (kernel resource monitor) is not running. Issue When ioscan is run with the -fn or -Fn option and kernel resource monitor (krm) is not running, there could be stale krm device files in the system which would correspond to different devices, including fcd, in ioscan output.
FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v2 Release Notes Related Documentation Related Documentation Complete Fibre Channel documentation is available on http://www.docs.hp.com under the Networking and Communications section in the Fibre Channel category, or directly at: http://www.docs.hp.com/hpux/netcom/index.