Following are the known problems and workarounds in the HP PCI Tachyon XL2 Fibre Channel driver:
• Problem: During online replacement (OLR) of the A6795A adapter in Superdome systems, the
replacement can fail if the adapter is connected to the hub, switch, or device, and the following error
message is displayed:
OLARD error: General error
The slot is inaccessible till you power cycle the system.
Workaround: Disconnect the cable from the adapter before you perform online addition and replacement
(OLAR) operations.
• Problem: During online replacement (OLR) of the A6795A adapter on L3000 systems, the replacement
can cause a system panic (high-priority machine check (HPMC)) if the adapter is connected to the hub,
switch, or device. The subsequent boot hangs unless you power cycle the system.
Workaround: Disconnect the cable from the adapter before you perform the OLAR operations.
• Problem: During online replacement (OLR) of the A6795A adapter on the L2000 system, the
replacement may fail and the following error message may be displayed:
OLARD error: General error
Workaround: This problem is fixed in Processor Dependent Code (PDC) Version 41.38.