HP 3PAR OS 3.1.2 MU2 Patch 19 Upgrade Instructions

If the basic SP processes differ after the patch installation, see the HP 3PAR Service Processor
Software Troubleshooting Guide.
17. To return to the previous menu, press Enter.
18. Continue to “Install the Patch on the HP 3PAR OS” (page 11)
Installing the Patch from a CD
If you are installing the patch on-site, you can install the patch from the patch CD.
1. Insert the HP 3PAR 3.1.2 MU2 Patch P19 Software CD (P/N QR482-10037) into the SP.
2. From the SPMAINT main menu, enter: =1.16.1 (Update SP Software Revision).
3. Enter the number corresponding to CDROM.
4. At the confirmation, enter: y.
When the patch installation process is complete, the SPMAINT main menu appears.
5. Enter: =1.1 (Display SP Version).
6. Verify that the InFormOS patches (3.1.2) entry displays 19.
7. Compare the post-upgrade SP processes with the pre-upgrade SP processes listed before you
applied the patch. For an example of the basic list, see the Example of Basic SP Processes
(page 6).
If the basic SP processes are running, you can now install the patch on the storage system.
If the basic SP processes differ after the patch installation, refer to the HP 3PAR Service
Processor Software Troubleshooting Guide.
8. Remove the CD from the SP and place it in the storage system cabinet and continue to “Install
the Patch on the HP 3PAR OS” (page 11).
10 Obtain and Install the Patch on the SP