HP 3PAR Windows 2012 and Windows Server 2008 Implementation Guide

HP 3PAR HBA 4G: 1638
HP 3PAR HBA 8G: 3276 (HP 3PAR StoreServ 10000 and HP 3PAR StoreServ 7000
systems only)
The I/O queues are shared among the connected host HBA ports on a first-come, first-served
basis.
When all queues are in use and a host HBA port tries to initiate I/O, it receives a target queue
full response from the HP 3PAR StoreServ Storage port. This condition can result in erratic I/O
performance on each host . If this condition occurs, each host should be throttled so that it
cannot overrun the HP 3PAR StoreServ Storage port's queues when all hosts are delivering
their maximum number of I/O requests.
NOTE: When host ports can access multiple targets on fabric zones, the assigned target
number assigned by the host driver for each discovered target can change when the host is
booted and some targets are not present in the zone. This situation may change the device
node access point for devices during a host reboot. This issue can occur with any
fabric-connected storage, and is not specific to the HP 3PAR StoreServ Storage.
HP 3PAR Priority Optimization
The HP 3PAR Priority Optimization feature introduced in HP 3PAR OS version 3.1.2. MU2 is a
more efficient and dynamic solution for managing server workloads and can be utilized as an
alternative to setting host I/O throttles. Using this feature, a storage administrator is able to share
storage resources more effectively by enforcing quality of service limits on the array. No special
settings are needed on the host side to obtain the benefit of Priority Optimization although certain
per target or per adapter throttle settings may need to be adjusted in rare cases. For complete
details of how to use Priority Optimization (Quality of Service) on HP 3PAR arrays, please read
the HP 3PAR Priority Optimization technical white paper available at the following website:
HP 3PAR Priority Optimization
HP 3PAR OS Persistent Ports
The HP 3PAR OS Persistent Ports (or virtual ports) feature minimizes I/O disruption during an
HP 3PAR StoreServ Storage online upgrade or node-down event (online upgrade, node reboot,
or cable pull test). Port shutdown or reset events do not trigger this feature.
Each FC target storage array port has a partner array port automatically assigned by the system.
Partner ports are assigned across array node pairs.
HP 3PAR OS Persistent Ports allows an HP 3PAR StoreServ Storage FC port to assume the identity
(port IP address) of a failed port while retaining its own identity. Where a given physical port
assumes the identity of its partner port, the assumed port is designated as a persistent port. Array
port failover and failback with HP 3PAR OS Persistent Ports is transparent to most host-based
multipathing software, which can keep all of its I/O paths active.
NOTE: Use of HP 3PAR OS Persistent Ports technology does not negate the need for properly
installed, configured, and maintained host multi-pathing software.
For a more complete description of the HP 3PAR OS Persistent Ports feature, its operation, and a
complete list of required setup and connectivity guidelines, see:
the HP Technical white paper HP 3PAR StoreServ Persistent Ports (HP document
#F4AA4-4545ENW)
This document is available on the following HP SC website:
22 Performing Preliminary HP 3PAR StoreServ Storage and Host Configuration