HP 3PAR VMware ESX Implementation Guide
Table Of Contents
- HP 3PAR VMware ESX Implementation Guide
- Contents
- 1 Introduction
- 2 Configuring the HP 3PAR StoreServ Storage for Fibre Channel
- 3 Configuring the HP 3PAR StoreServ Storage for iSCSI
- 4 Configuring the HP 3PAR StoreServ Storage for FCoE
- 5 Configuring the Host for a Fibre Channel Connection
- Installing the HBA and Drivers
- Installing Virtual Machine Guest Operating System
- Multipath Failover Considerations and I/O Load Balancing
- Performance Considerations for Multiple Host Configurations
- ESX/ESXi 4.1, ESXi 5.x Additional Feature Considerations
- Storage I/O Control
- vStorage APIs for Array Integration (VAAI)
- HP 3PAR VAAI Plugin 1.1.1 for ESX 4.1
- HP 3PAR VAAI Plugin 2.2.0 for ESXi 5.x
- UNMAP (Space Reclaim) Storage Hardware Support for ESXi 5.x
- Out-of-Space Condition for ESX 4.1 and ESXi 5.x
- Additional New Primitives Support on ESXi 5.x
- VAAI and New Feature Support Table
- VAAI Plugin Verification
- 6 Configuring the Host as an FCoE Initiator Connecting to a FC target or an FCoE Target
- 7 Configuring the Host for an iSCSI Connection
- Setting Up the Switch, iSCSI Initiator, and iSCSI target ports
- Installing iSCSI on VMware ESX
- Installing Virtual Machine Guest Operating System
- Creating a VMkernel Port
- Configuring a Service Console Connection for the iSCSI Storage
- Configuring the VMware SW iSCSI Initiator
- iSCSI Failover Considerations and Multipath Load Balancing
- Performance Considerations for Multiple Host Configurations
- ESX/ESXi Additional Feature Considerations
- 8 Allocating Storage for Access by the ESX Host
- 9 Booting the VMware ESX Host from the HP 3PAR StoreServ Storage
- 10 Support and Other Resources
- 11 Documentation feedback
- A Appendix

The maximum number of LUNs on a single ESX HBA port is 256, and 256 total LUNs on the ESX
host. Internal devices, such as local hard drives and CD drives, are counted as a LUN in the ESX
host LUN count.
Removing Volumes
After removing a VLUN exported from the HP 3PAR StoreServ Storage, perform a ESX host bus
adapter rescan. ESX will update the disk inventory upon rescan (Figure 42 (page 79)). This applies
to both FC and iSCSI.
Figure 42 Rescanning the ESX Host
It is advisable to remove the disk/LUN from the virtual machine inventory, detach from the ESX
host, and then remove it from the HP 3PAR StoreServ Storage using the removevlun and
removevv HP 3PAR OS CLI commands or using the HP 3PAR Management Console. If a LUN is
not detached but is removed from the HP 3PAR StoreServ Storage, it appears as a device in an
error state, and is cleared after an ESX host reboot.
Figure 43 Detaching a LUN
Removing Volumes 79