HP StorageWorks XP Cluster Extension Software Administrator Guide (T1656-96035, April 2010)

Syntax
clxchkmon [-clx] [-s host name] [-n resource_name —g device_group] [[-t
monitor_interval | -autorecover mode | -remove [-force] | -show | -pid | -stopsrv
| -log [error | warning | info | trace]]] [-p port number]
where:
-s hostname Specifies the name of a host.
–n resource_name Specifies the resource (application) name as used in XP Cluster
Extension.
–g device_group Specifies an XP RAID Manager group name.
–t monitor_interval Specifies interval in seconds to update registered monitor resources.
–autorecover mode Specify YES to enable autorecovery, or NO to disable autorecovery
for registered monitor resource.
–clx Executes the command only for XP Cluster Extension resources.
–remove Removes the resource from the monitor list.
–force Disables user confirmation to remove resource.
–show Displays monitored resources.
—pid Returns the process ID of the pair/resync monitor.
–stopsrv Stops the pair/resync monitor socket server.
–log Sets the log level for the pair/resync monitor.
–p port_number Specifies the port number to be used.
Return codes
clxchkmon exits with one of the following return codes:
0 Successful, or device group is in PAIR state.
1 Device group is not in PAIR state.
2 Resource/device group is not registered with the pair/resync monitor.
3 Pair/resync monitor (clxchkd) is not running.
4 Device group's pair status is pending.
10 Pair/resync monitor internal error.
XP Cluster Extension and CLI116