HP XP Cluster Extension Software Administrator Guide

To configure RAID Manager advanced properties from the Failover Cluster Management HP XP
CLX Settings tab or the resource configuration tool:
1. Click the Advanced button to open the Advanced Fence Level Failover Behavior window. The
available settings in this window depend on the fence level used with your device/copy
groups.
For the DATA fence level, you can update the Data lose mirror and DATA lose data center
values. See “DataLoseDataCenter” (page 71) and “DataLoseMirror” (page 72) for more
information about these values.
For the ASYNC fence level, you can update the ASYNC takeover timeout value. See
AsyncTakeoverTimeout” (page 69) for more information about this value.
For the journal fence level, you can update the Journal data currency on S-VOL and
ASYNC takeover timeout values. See “JournalDataCurrency” (page 73) and
AsyncTakeoverTimeout” (page 69) for more information about these values.
2. Update the settings as needed, and then click OK to close the window.
3. Click OK to save your changes and close the window.
Configuring HP XP Cluster Extension resources 29