3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

6.17
Using the Component LEDs
InForm OS Version 2.2.4
3PAR Confidential
Figure 6-9. Battery Backup Unit LEDs (Magnetek)
Consult Table 6-8 to verify proper functioning of the BBUs.
Table 6-8. Battery Backup Unit LED Displays
LED Appearance Meaning
Battery A status LED Steady green light Indicates that battery A is charged.
Flashing green light Indicates that the battery is
undergoing a test.
Steady amber light Indicates a battery error.
No light BBUs or power supply is turned
off.
Battery B status LED Steady green light Indicates that battery B is charged.
Blinking green light Indicates that the battery is
undergoing a test.
Steady amber light Indicates a battery error.
No light BBUs or power supply is turned
off.
0260_L_R1
Battery A
Status LED
Battery B
Status LED