3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

7.11
Using the Component LEDs
InForm OS Version 2.2.4
3PAR Confidential
7.1.2.2 DC2 Drive Magazine LEDs
DC2 drive magazines contain the following LEDs, see Figure 7-6.
Flashing amber light (1 blink
per second)
The drive cage has some type of
error, for example a failed or
missing power supply, but is
communicating with a node.
Rapid toggle between amber
and green light
Indicates a cage firmware
upgrade initiated by the
upgradecage CLI command is
in progress. A firmware upgrade
normally takes less than two
minutes to complete.
Hot-plug Steady amber light Indicates FC-AL module is
prepared for replacement (hot-
plug).
No light Indicates FC-AL module is not
prepared for hot-plug.
Split Mode Steady green light Indicates the drive cage is split
into two logical portions.
No light Indicates the drive cage is not
split.
Table 7-2. DC4 Drive Cage FC-AL Module LED Displays (continued)
LED Appearance Meaning