3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

7.28
Using the Component LEDs
InForm OS Version 2.2.4
3PAR Confidential
Figure 7-16. Battery Backup Unit LEDs (Magnetek)
Consult Table 7-13 to verify proper functioning of the BBUs.
7.1.9 Power Distribution Unit Lamps
The InServ S-Class Storage Servers include four power distribution units (PDUs). PDUs contain
two power bank lamps (Figure 7-17):
Table 7-13. Battery Backup Unit LED Displays
LED Appearance Meaning
Battery A status LED Steady green light Indicates battery A is charged.
Blinking green light Battery is undergoing a test.
Steady amber light Indicates battery error.
Battery B status LED Steady green light Indicates battery B is charged.
Blinking green light Battery is undergoing a test.
Steady amber light Indicates battery error.
0260_L_R1
Battery A
Status LED
Battery B
Status LED