3PAR InForm® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

9.8
Using the Component LEDs
InForm OS Version 2.2.4
3PAR Confidential
9.1.3.2 FCAL Module LEDs
The InServ E-Class Storage Server drive chassis contains two FCAL modules. FCAL module LEDs
are as follows:
System Fault
LED
Steady
amber light
Indicates the following:
Test state (5 seconds), if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is steady
amber.
Invalid Address LED is steady amber.
2 Gb Link Speed LED is steady amber.
Processor module in FCAL failure, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is off.
Unknown FCAL module type installed, 12C Bus failure, or
backplane autostart watchdog failure, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is off.
Ops to ESI communication failure, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is flashing.
Flashing
amber light
Indicates the following:
Over or under temperature, if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is steady
amber.
Power supply is removed and system power redundancy check
option is set, if:
Power On LED is steady green.
Power Supply/Cooling/Temperature Fault LED is flashing.
No drives fitted, if:
Power ON LED is steady green.
Power Supply/Cooling/Temperature Fault LED is off.
Table 9-2. Drive Chassis OPs Panel LED Meanings (continued)
LED Appearance Meaning