3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

10.2
Powering Off the Storage Server
InForm OS Version 2.2.4
3PAR Confidential
5 Select option 6, Halt an InServ cluster/node.
6 Select the desired InServ Storage Server.
7 Select option a, all and respond to the confirmation prompts.
8 Press
X to return to the 3PAR Service Processor Menu.
The InServ Storage Server will now shutdown and halt. This may take several minutes.
9 Wait until the system has completed shutdown by observing that all controller nodes in the
system have the Hot-Plug LED solid amber and the Node Status LED blinking fast-green (a
rate of three blinks per second). See Figure 10-1 for the InServ T-Class Storage Server,
Figure 10-2 for the S-Class Storage Server, Figure 10-3 for the InServ F-Class Storage Server,
and Figure 10-4 for the InServ E-Class Storage Servers.
Figure 10-1. InServ T-Class Server Hot-Plug LED and Node Status LED
CAUTION: Failure to wait until all controller nodes are in a halted state as
defined in step 9 could cause the system to view the shutdown as uncontrolled
and place the system in a checkld state upon power up. This can seriously impact
host access to data.
0601_L_R3
Node
Hot-plug LED
Node Status LED