3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.8
InForm OS Version 2.2.4
3PAR Confidential
MESSAGE CODE
0x300de
TYPE
Component state change
MESSAGE
Port <port_id> Node <node_id> Slot <slot_id> Degraded (<list of
states>)
STATE 1
Intermittent CRC Errors Detected
SUGGESTED ACTION
Replace the fibre channel cable. If the problem persists after cable replacement, contact your
local service provider for technical support and services.
STATE 2
Target Mode Port Went Offline
SUGGESTED ACTION
May be caused by a pulled cable or the HBA being reset due to an internal error. If there is an
HBA core dump file present in
/var/core/hba on the master node, send the information to
your local service provider for analysis.
STATE 3
Firmware Coredump
SUGGESTED ACTION
Contact your local service provider for technical support and services.