3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.9
InForm OS Version 2.2.4
3PAR Confidential
MESSAGE CODE
0x300fa
TYPE
Component state change
MESSAGE
Port <port_id> Node <node_id> Slot <slot_id> Failed (<list of states>)
STATE 1
Down due to reset failure
SUGGESTED ACTION
The HBA failed to reset. This may be caused by a hardware failure on the HBA. Replace the
HBA.
STATE 2
Down due to missing firmware file
SUGGESTED ACTION
Points to improper software installation of the InForm OS. Contact your local service provider
for technical support and services.
STATE 3
Shutdown due to too many firmware cores
SUGGESTED ACTION
The HBA port is getting multiple fatal errors in succession. Send the firmware cores and the
event log to your local service prover for analysis.
STATE 4
Shutdown due to too many internal errors
SUGGESTED ACTION
The HBA port is getting multiple internal errors. Use CLI command controlport rst -l to
hard reset the HBA port. Replace the HBA if the problem persists.