3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.26
InForm OS Version 2.2.4
3PAR Confidential
SUGGESTED ACTION
The PD specified in the alert has been marked failed because a command sent to check if disk is
ready has failed. Use the CLI command showpd <pd_id> to confirm the disk is still in this
state.
The failure could be intermittent and a retry might fix it. As above, the suggested action is to
wait for a few minutes to see if the alert is auto-fixed. If not, contact your local service provider
for possible disk replacement.
STATE 4
Read Capacity Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because a command sent to read its
capacity has failed. Use the CLI command showpd <pd_id> to confirm the disk is still in this
state.
A disk is marked failed if a SCSI inquiry to check its capacity fails. This error is also intermittent
and might get fixed if the SCSI inquiry succeeds on a retry. As above, the suggested action is to
wait for a few minutes for the retry to fix it. If not, contact your local service provider for a
possible disk replacement.
STATE 5
Write Label Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the disk label could not be
written to the disk. Use the CLI command
showpd <pd_id> to confirm the disk is still in this
state.
If the error is persistent, contact your local service provider for possible disk replacement.
STATE 6
Mod Page Update Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because its mod pages could not be
updated. Use the CLI command
showpd <pd_id> to confirm the disk is still in this state.
If the error is persistent, contact your local service provider for possible disk replacement.