3PAR InForm® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.40
InForm OS Version 2.2.4
3PAR Confidential
MESSAGE CODE
0xe0002
TYPE
System manager cannot start up
MESSAGE 1
Cannot reach TOC quorum. Use “setsysmgr” to set system manager startup
state.
SUGGESTED ACTION
Attempt to get as many of the physical disks online as possible before proceeding.
If the system software has not been recently upgraded, run
showsysmgr to gather more
information about the problem and a list of valid TOCs.
MESSAGE 2
TOC quorum found for TOC <TOC_generation_number>, but waiting for nodes
<node_ids> to boot up. If the nodes are offline, use “setsysmgr tocgen
<TOC_generation_number>”.
SUGGESTED ACTION
Some nodes have not joined the cluster. Try to rejoin the nodes to the cluster. If this fails, run
setsysmgr tocgen <TOC_generation_
number>
, where <TOC_generation_number> is shown in the alert.
MESSAGE 3
TPD system is waiting for manual startup. Use “setsysmgr” to set system
manager startup date.
SUGGESTED ACTION
The file /manualstartup has been created on one or more nodes. Remove it from all nodes
and run setsysmgr to proceed. Normally, running setsysmgr tocgen starts the system.
NOTE: The Table of Contents (TOC) generation number is an identifying
number that distinguishes each modified version of the TOC from its predecessor.
Normally, the largest numbered generation is the one that is valid.