3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.78
InForm OS Version 2.2.4
3PAR Confidential
MESSAGE CODE
0x1b00fa
TYPE
Component State Change.
MESSAGE
Node <node_id> Power Supply <power_supply_id> Failed (<list of states>)
STATE 1
Invalid Battery Count
SUGGESTED ACTION
Replace power supply and battery.
STATE 2
DC Failure
SUGGESTED ACTION
If an AC failure accompanies this DC failure, ignore the DC failure until the AC failure is
resolved.
DC failure may indicate that the power supply has been switched off by software or manually.
Make sure the power supply is fully seated and the on/off switch is ON. If there is not an AC
failure, the power switch is on, and the power supply is fully inserted, replace the power
supply.
STATE 3
AC Failure
SUGGESTED ACTION
Check the AC cables and ensure the AC connection is good. If the AC connection is good but
the power supply still reports an AC failure, replace the power supply.
STATE 4
Fan Failure