3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.89
InForm OS Version 2.2.4
3PAR Confidential
SUGGESTED ACTION
Internal midplane hardware error. Power cycle cage. If error persists, replace midplane.
MESSAGE 53
Midplane LM87 voltage/temperature under limit (<code>)
SUGGESTED ACTION
Midplane voltage sensor reports low voltage. Replace power supplies. If error persists, replace
midplane.
MESSAGE 54
Midplane LM87 voltage/temperature over limit (<code>)
SUGGESTED ACTION
Midplane voltage sensor reports high voltage. Replace power supplies. If error persists, replace
midplane.
MESSAGE 55
Midplane LM87 start failure
SUGGESTED ACTION
Internal midplane hardware error. Power cycle cage. If error persists, replace midplane.
MESSAGE 56
Firmware panic due to <reason>.Panic count is <count> (<code>)
SUGGESTED ACTION
Midplane hardware or software error. If you receive this message, then the cage completed
self-recovery. If error persists, replace midplane. If a cage firmware core dump is available, a
separate message code 0x1e0005 will also be present. A cage firmware core dump can be
analyzed by your service provider.