3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.94
InForm OS Version 2.2.4
3PAR Confidential
Check if the cables are properly seated. Confirm the loop is off line by running CLI command
showpd -degraded and showpd -failed.
STATE 9
Single ESI Port
SUGGESTED ACTION
The cage has only one ESI PD online. A disk in the ESI position may be off line. Use the CLI
command showpd -p -cg <cage_name> to verify if any disks are off line. If a PD is off-line
due to a Servicemag operation or other service operation, the alert will auto resolve. Contact
your local service provider for technical support and services.
Validate the alert by running CLI command showpd -degraded and showpd -failed. If ESI
PDs are intentionally off line, reconnect them. Replace PDs if they are failing.