If the disk has disappeared from the B loop,it reports its B loop as missing. This could also occur
because of a servicemag operation or a controlmag offloop operation.
Contact your local service provider for technical support and services.
STATE 9
Relocating
SUGGESTED ACTION
This is only an activity flag which refers to the fact that chunklets from the disk are relocating.
The relocations could be because of an active service operation or because of intermittent
disturbances. No further action is required.
STATE 10
Servicing
SUGGESTED ACTION
This is a disk activity flag indicating the disk is being serviced. This flag will be set if a
servicemag or a servicecage operation is active on the disk.
STATE 11
Prolonged Missing A Port
SUGGESTED ACTION
Port A is missing for over 4 minutes. Check if the PD port is missing by issuing CLI command
showpd and showcage -d. If only one port is missing, the PD may need to be replaced.
Contact your local service provider for technical support and services.
STATE 12
Prolonged Missing B Port
SUGGESTED ACTION
Port B is missing for over 4 minutes. Check if the PD port is missing by issuing CLI command
showpd and showcage -d. If only one port is missing, the PD may need to be replaced.
Contact your local service provider for technical support and services.
STATE 13
Cage State Missing