3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

11.11
InForm OS Version 2.2.4
3PAR Confidential
MESSAGE CODE
0x230003
TYPE
Port shutdown on fatal error
MESSAGE
Port <port_id> shut down: <time_shutdown>
SUGGESTED ACTION
1 Ensure the port settings are correct for the type of connection. For example, if the port is
connected to a fabric switch or hub, the port persona should be one of the fabric
connection types (7,8,9):
controlport persona 7 n:s:p
2 Ensure the device connected on the port is functioning correctly. Perhaps by power-cycling
the device and issuing controlport rst n:s:p to reset the port and see if the new port
now functions correctly.
3 Verify that the problem is not port-specific by swapping the cable with a known working
port.
4 If the problem persists, contact your local service provider.
NOTE: This will reset the port. If the port continues to generate firmware cores, it
will shut down again and the alert reposted.