3PAR InFormĀ® OS 2.2.4 Messages and Operator's Guide (320-200119 Rev A, March 2009)

6.6
Using the Component LEDs
InForm OS Version 2.2.4
3PAR Confidential
6.1.2.2 Drive Magazine LEDs
Drive magazines contain the following LEDs (Figure 6-3):
Rapid toggle between amber
and green light
Indicates a cage firmware
upgrade initiated by the
upgradecage CLI command is
in progress. A firmware upgrade
normally takes less than two
minutes to complete.
Hot-plug Steady amber light Indicates FC-AL module is
prepared for replacement (hot-
plug).
No light Indicates FC-AL module is not
prepared for hot-plug.
Split Mode Steady green light Indicates the drive cage is split
into two logical portions.
No light Indicates the drive cage is not
split.
4 GB/s Steady green light Indicates that the transfer rate is
operating at 4 Gb/s.
No light Indicates that the transfer rate is
operating at 2 Gb/s.
Table 6-1. Drive Cage DC4 FC-AL Module LED Displays (continued)
LED Appearance Meaning