3PAR CIM API Programming Reference for InForm OS 2.3.1 (320-200164 Rev B, February 2010)

A.29
3PAR_TPD.mof
InForm OS Version 2.3.1 CIM API Programming Reference
"Fabric"} ]
uint16 Topology;
[Description ("Daisy chain configuration of the port"),
ValueMap {"0", "1", "2"},
Values {"Unknown", "Valid", "Invalid"} ]
uint16 Configuration;
[Description ("Mode of the port"),
ValueMap {"0", "1", "2"},
Values {"Suspended", "Target", "Initiator"} ]
uint16 Mode;
[Description ("Shows if the mode change is allowed or not.")]
boolean ModeChangeAllowed;
[Description ("Node WWN of the port.") ]
uint64 NodeWWN;
[Description ("Describes device type this port is connected to."),
ValueMap {"0", "1", "2", "3", "4"},
Values {"Free", "Host", "Disk", "IPort", "FCRC"} ]
uint16 DeviceTypeConnected;
[Description ("List of devices, this port is connected to.") ]
string ConnectedTo;
[Description ("Persona of the port.") ]
uint16 Persona;
[Description ("Connection type."),
ValueMap {"0", "1", "2", "3"},
Values {"Unknown", "Loop", "Point-to-Point", "Loop Point-to-Point"} ]
uint16 ConnectionType;
[Description ("Class 2 support."),
ValueMap {"0", "1", "2", "3"},
Values {"Unknown", "ack0", "ack1", "Disable"} ]
uint16 Class2Support;
[Description ("VLUN Change Notification (VCN) support."),
ValueMap {"0", "1", "2"},
Values {"Unknown", "Enable", "Disable"} ]
uint16 VCN;