Table 1 Modifications to the InForm OS (continued)
DescriptionItemBug ID
When System Manager attempted to create a copy of itself to handle a showspace
request and the copy creation failed, the generated event was not parsed correctly
Out of memory condition
caused by improper
parsing of events
60638
and resulted in repeated failures by the event filter. This caused events to be queued
generated by System
Manager.
in memory indefinitely, resulting in an out of memory situation, especially in
configurations using Remote Copy.
The events generated by System Manager are now parsed correctly and out of
memory problems are avoided.
A Remote Copy miscompare between the primary and secondary volumes was
occurring after a node went down while IO was being received which spanned two
logical disks with different owners.
A Remote Copy
comparison error occurs
between the primary and
61212
Remote Copy requests are now properly issued after a backup node completes the
IO to the base volume on the primary.
secondary volumes after
a node goes down.
The Logical Unit Reset task management command received on 4Gb fibre channel
ports was not properly releasing SCSI-2 reservations for addressed LUNs.
SCSI-2 reservations on
addressed LUN not
61315
Handling of the Logical Unit Reset task management function has been modified to
ensure that SCSI-2 reservations on an addressed LUN are released appropriately.
properly released by
Logical Unit Reset Task
Management command.
Limitations of the InForm OS
Connectivity Issues with Remote Copy IP Interfaces for 100Mbps Switch Ports
HP has observed connectivity issues with Remote Copy IP interfaces connected to 100Mbps switch
ports that can cause the Remote Copy links to negotiate their speed and duplex settings incorrectly.
This issue has the potential to cause the Remote Copy IP links, as well as the connected switch ports,
to stop working (e.g., states of offline, down, unknown, loss_sync). In many cases, the HP controller-node
has to be rebooted to clear this condition.
In some configurations, depending on switch type and InForm OS version, selecting Auto-negotiation
has overcome the problem, while in others, forcing the ports to 100/Full has provided relief. In all
cases, utilizing a 1Gbps switch port has alleviated all negotiation issues.
To resolve this issue, HP requires all Remote Copy IP ports to be connected to a 1Gbps switch port in
order to alleviate the observed connectivity and negotiation related problems.
This reduction in functionality is described in Product_Alert_247 200011-RevA_RCIP_Link_Speed.
Known Issues with the InForm OS
RPI Resources Exceeded for Fibre Channel Ports (Bug 61125)
Each 4Gb fibre channel port on the storage system has 511 Remote Port Indicator (RPI) resources.
One resource is used when an initiator logs in. When the initiator logs out or gets disconnected, the
RPI is not released. If the initiator logs back in with the same fibre channel D_ID, the RPI gets reused,
but if it logs in with a different D_ID, the original RPI is lost. After 511 such logins, the resource is
completely exhausted and all further logins are blocked.
The resource counts in use on the 4Gb fibre channel ports as indicated are output to the debug eventlog
every hour. Here is an example that shows that the port has 0x1c7 (455) RPI resources available.
2011-05-03 11:22:34.44 CEST 3 580016 Notification Debug
nl
Notification undefined Port 3:5:4: Max xri: 0x800, iocb: 0x8ce, rpi:
nl
0x200; Avail xri: 0x7fe, iocb: 0x8ce rpi: 0x1c7; HBQ count r0: 1983,
nl
r1: 127 cmds: 2
8 HP 3PAR InForm Operating System Release Notes