After configuring zoning and connecting each host HBA port and HP 3PAR StoreServ Storage port
to the fabric(s), verify the switch and zone configurations using the HP 3PAR OS CLI showhost
command, to ensure that each initiator is zoned with the correct target(s).
HP 3PAR Coexistence
The HP 3PAR StoreServ Storage array can coexist with other HP array families.
For supported HP arrays combinations and rules, see the HP SAN Design Reference Guide, available
on the HP website:
HP Support Center
HP SAN Design Reference Guide
Configuration Guidelines for Fabric Vendors
Use the following fabric vendor guidelines before configuring ports on fabric(s) to which the
HP 3PAR StoreServ Storage connects.
Brocade switch ports that connect to a host HBA port or to an HP 3PAR StoreServ Storage
port should be set to their default mode. On Brocade 3xxx switches running Brocade firmware
3.0.2 or later, verify that each switch port is in the correct mode using the Brocade telnet
interface and the portcfgshow command, as follows:
brocade2_1:admin> portcfgshow
Ports 0 1 2 3 4 5 6 7
-----------------+--+--+--+--+----+--+--+--
Speed AN AN AN AN AN AN AN AN
Trunk Port ON ON ON ON ON ON ON ON
Locked L_Port .. .. .. .. .. .. .. ..
Locked G_Port .. .. .. .. .. .. .. ..
Disabled E_Port .. .. .. .. .. .. .. ..
where AN:AutoNegotiate, ..:OFF, ??:INVALID.
The following fill-word modes are supported on a Brocade 8 G/s switch running FOS firmware
6.3.1a and later:
admin>portcfgfillword
Usage: portCfgFillWord PortNumber Mode [Passive]
Mode: 0/-idle-idle - IDLE in Link Init, IDLE as fill word (default)
1/-arbff-arbff - ARBFF in Link Init, ARBFF as fill word
2/-idle-arbff - IDLE in Link Init, ARBFF as fill word (SW)
3/-aa-then-ia - If ARBFF/ARBFF failed, then do IDLE/ARBFF
HP recommends that you set the fill word to mode 3 (aa-then-ia), which is the preferred
mode using the portcfgfillword command. If the fill word is not correctly set, er_bad_os
counters (invalid ordered set) will increase when you use the portstatsshow command
while connected to 8 G HBA ports, as they need the ARBFF-ARBFF fill word. Mode 3 will
also work correctly for lower-speed HBAs, such as 4 Gb/2 Gb HBAs. For more information,
see the Fabric OS Command Reference Manual and the FOS release notes, available on the
Brocade website:
Brocade
In addition, some HP switches, such as the HP SN8000B 8-slot SAN backbone director switch,
the HP SN8000B 4-slot SAN director switch, the HP SN6000B 16 Gb FC switch, or the HP
SN3000B 16 Gb FC switch automatically select the proper fill-word mode 3 as the default
setting.
McDATA switch or director ports should be in their default modes as G or GX-port (depending
on the switch model), with their speed setting permitting them to autonegotiate.
14 Configuring the HP 3PAR StoreServ Storage for Fibre Channel