Contact your local service provider for possible disk replacement.
STATE 10
Invalid Type
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the vendor of the disk is not included
in the list of supported vendors. Use the CLI command showpd <pd_id> to confirm the disk is
still in this state.
A physical disk drive has failed and requires replacement.
Contact your local service provider for possible disk replacement.
STATE 11
Invalid Firmware
SUGGESTED ACTION
The PD specified in the alert has been marked failed because it has unsupported drive firmware
on it. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
STATE 12
Invalid Block Size
SUGGESTED ACTION
The PD specified in the alert has been marked failed because it is reporting an unsupported block
size. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
A physical disk drive has failed and requires replacement.
Contact your local service provider for possible disk replacement.
STATE 13
Invalid Cage
SUGGESTED ACTION
The PD specified in the alert has been marked temporarily failed because it does not have a known
cage position. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
If the error persists, contact your local service provider for possible disk replacement.
A physical disk drive has failed and requires replacement.
STATE 14
Prolonged Not Ready
SUGGESTED ACTION
The PD specified in the alert has been marked failed because it has been marked not ready for
more than 20 minutes. Use the CLI command showpd <pd_id> to confirm the disk is still in this
state.
Contact your local service provider for possible disk replacement.
123