HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

LM94 Temp: 23 C 0 C 65 C Within Tolerance
LM87 Temp: 25 C 0 C 65 C Within Tolerance
LM87 Ext Temp: 23 C -10 C 65 C Within Tolerance
CPU0 Temp: 25 C 0 C 85 C Within Tolerance
CPU1 Temp: 28 C 0 C 85 C Within Tolerance
CPU0 VRM Temp: n/a n/a n/a Within Tolerance
CPU1 VRM Temp: n/a n/a n/a Within Tolerance
CPU DIMM0 Temp: 38 C 0 C 105 C Within Tolerance
CPU DIMM1 Temp: 36 C 0 C 105 C Within Tolerance
NOTE: These tables are examples of environmental readings from nodes. The specific output for
your node may vary.
SUGGESTED ACTION
Use the shownodeenv command to get current readings of system temperatures and voltages. If
a temperature limit has been exceeded, verify the system has adequate ventilation and ambient
temperature.
An event has occurred on your system which requires attention. An environmental reading from
the specified node returned an error condition for Voltage or Temperature or there was an issue
communicating with the sensor. Investigate the source of the Error_code and the environmental
conditions. Contact your authorized support provider for assistance if required.