HP 3PAR InForm OS 3.1.1 Messages and Operators Guide
MESSAGE CODE
0x01a001d
TYPE
Node-Failure-Analysis File Received From Remote/Local MCU
MESSAGE
Node-Failure-Analysis file received from Node %d
SUGGESTED ACTION
There was a Node Failure Analysis file on the NEMOE that has been saved. Contact your local
service provider for technical support and services.
An event has occurred on your system which requires attention. Please contact your authorized
support provider for assistance.
0x01a00de
TYPE
Component State Change
STATE 1
Time-Of-Day Battery Failure
SUGGESTED ACTION
Replace the time-of-day battery.
STATE 2
Invalid Battery Configuration
SUGGESTED ACTION
Check the power supply and battery cables for proper connection. If connected properly, replace
the cables.
STATE 3
CPU Overheating
SUGGESTED ACTION
Use the shownodeenv command to view current system temperatures and voltages. If a temperature
limit has been exceeded, verify the system has adequate ventilation and ambient temperature.
If temperature or voltage limit is exceeded, contact your local service provider for technical support
and services.
STATE 5
Control Cache DIMM Overheating
SUGGESTED ACTION
Use the shownodeenv command to view current system temperatures and voltages. If a temperature
limit has been exceeded, verify the system has adequate ventilation and ambient temperature. If
174 Alerts