HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

SUGGESTED ACTION
FCAL failed to initialize. Replace FCAL.
Contact your authorized support provider for assistance if required.
MESSAGE 38
POST FCAL EEPROM Test <error> <code>.
SUGGESTED ACTION
FCAL EEPROM failed during functional test. Replace FCAL.
Contact your authorized support provider for assistance if required.
MESSAGE 39
POST Power Supply Init <error> <code>.
SUGGESTED ACTION
The power supply failed to initialize during the power on self test. Replace the power supply.
Contact your authorized support provider for assistance if required.
MESSAGE 40
POST Power Supply Probe <error> <code>.
SUGGESTED ACTION
Power supply failed during functional test. Replace the power supply.
Contact your authorized support provider for assistance if required.
MESSAGE 41
POST Power Supply EEPROM Test <error> <code>.
SUGGESTED ACTION
Power supply EEPROM failed during functional test. Replace the power supply.
Contact your authorized support provider for assistance if required.
MESSAGE 42
POST Power Supply Test <error> <code>.
SUGGESTED ACTION
Error has occurred during the power on self test. The ESI channel failed to initialize. Replace the
midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 43
POST ESI Test <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. ESI channel failed to initialize. Replace midplane.
Contact your authorized support provider for assistance if required.
192 Alerts