MESSAGE 44
POST ESI Init <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. ESI channel failed to initialize. Replace midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 45
POST PMC Alive Test <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. ESI channel failed to initialize. Replace midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 46
POST PMC Loopback Test <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. PMC switch chip failed POST internal loopback. Replace
midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 47
POST PMC Interchip Test <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. PMC switch chip failed interchip test. Replace midplane (or
possibly FCAL).
Contact your authorized support provider for assistance if required.
MESSAGE 48
POST SFP Test <error> <code>.
SUGGESTED ACTION
FCAL SFP failed functional test. Code 0x01: replace FCAL0. Code 0x02: replace FCAL1. Code
0x12: replace FCAL1 SFP0. Code 0x22: replace FCAL1 SFP1.
Contact your authorized support provider for assistance if required.
MESSAGE 49
POST Disk Loopback Test <error> <code>.
SUGGESTED ACTION
Error has occurred during the power on self test. The PMC switch chip failed the disk loopback
functional test. Replace the midplane (try reseating the loopback magazines first).
Contact your authorized support provider for assistance if required.