HP 3PAR InForm OS 3.1.1 Messages and Operators Guide
MESSAGE 50
POST Scheduler Init <error> <code>.
SUGGESTED ACTION
Internal midplane hardware error. Scheduler initialization failed. Reload cage firmware. If error
persists, replace midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 51
Midplane LM87 read failure
SUGGESTED ACTION
An internal midplane hardware error has occurred. Power cycle the cage. If the error persists,
replace the midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 52
Midplane LM87 voltage/temperature under limit (<code>)
SUGGESTED ACTION
Midplane voltage sensor reports low voltage. Replace power supplies, if necessary. If error persists,
replace midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 53
Midplane LM87 voltage/temperature over limit (<code>)
SUGGESTED ACTION
Midplane voltage sensor reports high voltage. Replace power supplies, If neccesary. If error persists,
replace midplane.
Contact your authorized support provider for assistance if required.
MESSAGE 54
Midplane LM87 start failure
SUGGESTED ACTION
An internal midplane hardware error has occurred. Power cycle the cage. If the error persists,
replace the midplane.
Contact your authorized support provider for assistance if required.An internal midplane hardware
error has occurred. .
MESSAGE 55
Firmware panic due to <reason>.Panic count is <count> (<code>)
SUGGESTED ACTION
A midplane hardware or software error has occurred. If you receive this message, then the cage
completed self-recovery. If the error persists, replace the midplane. If a cage firmware core dump