HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

STATE 26
Inquiry Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because a SCSI inquiry to it failed. Use the
CLI command showpd <pd_id> to confirm the disk is still in this state. A disk is marked failed
because a SCSI inquiry to it failed to gather information about its serial number, device ID, vendor
ID, etc. Generally this alert is auto-fixed when the SCSI inquiry is retried. Wait for a few minutes
to see if the alert is auto-fixed. If that does not happen, contact your local service provider for a
possible disk replacement.
A physical disk drive has failed and requires replacement.
STATE 27
Unit ReadyFailed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because a command sent to check if disk is
ready has failed. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
A physical disk drive has failed and requires replacement.
STATE 28
Read Capacity Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because a command sent to read its capacity
has failed. Use the CLI command showpd <pd_id> to confirm the disk is still in this state. A disk
is marked failed if a SCSI inquiry to check its capacity fails. This error is also intermittent and might
get fixed if the SCSI inquiry succeeds on a retry. As above, the suggested action is to wait for a
few minutes for the retry to fix it. If not, contact your local service provider for a possible disk
replacement.
A physical disk drive has failed and requires replacement.
STATE 29
Write Label Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the disk label could not be written
to the disk. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
A physical disk drive has failed and requires replacement.
STATE 30
Read Label Failed
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the disk label could not be read from
the disk. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
A physical disk drive has failed and requires replacement.
210 Alerts