HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

STATE 10
Invalid Type
SUGGESTED ACTION
The PD specified in the alert has been marked failed because the vendor of the disk is not included
in the list of supported vendors. Use the CLI command showpd <pd_id> to confirm the disk is
still in this state.
Contact your local service provider for technical support and services.
STATE 11
Invalid Firmware
SUGGESTED ACTION
The PD specified in the alert has been marked failed because it has unsupported drive firmware
installed. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
Contact your local service provider to reload the correct firmware on the disk.
STATE 12
Invalid Block Size
SUGGESTED ACTION
The PD specified in the alert has been marked failed because it is reporting an unsupported block
size. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
Contact your local service provider for technical support and services.
STATE 13
Invalid Cage
SUGGESTED ACTION
The PD specified in the alert has been marked temporarily failed because it does not have a known
cage position. Use the CLI command showpd <pd_id> to confirm the disk is still in this state.
Contact your local service provider for technical support and services.
STATE 14
Prolonged Not Ready
SUGGESTED ACTION
The PD specified in the alert has been marked failed because it has been marked not ready for
more than 20 minutes. Use the CLI command showpd <pd_id> to confirm the disk is still in this
state.
Contact your local service provider for technical support and services.
STATE 15
Prolonged Missing
216 Alerts