HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

MESSAGE CODE
0x02200de
TYPE
Component state change
MESSAGE 1
Degraded (list of states)
SUGGESTED ACTION
The battery in the specified power supply is showing a state of "not tested in 3 weeks" or the power
supply is showing AC/DC fail. Inspect the battery, power supply, power source, AC power cord,
power switch and PDU for issues. Replace if necessary.
MESSAGE 2
Node <node_id> Power Supply <power_supply_id> Battery <battery_id>
Degraded (<list of states>)
STATE 1
Expired
SUGGESTED ACTION
Verify the battery’s expiration date on its label. If the expiration date is incorrect, use the
setbattery command to correct the problem. If the battery is expired, replace the battery.
STATE 2
Charger Failed
SUGGESTED ACTION
Issue the CLI command, showbattery, if failure state, replace the battery.
STATE 3
Charger Over Current
SUGGESTED ACTION
Issue the CLI command, showbattery, if failure state, replace the battery
STATE 4
Charger Over Voltage
SUGGESTED ACTION
Issue the CLI command, showbattery, if failure state, replace the battery.
STATE 5
Charger Under Voltage
222 Alerts