HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

STATE 18
Not Engaged
SUGGESTED ACTION
Issue the CLI command, showbatterystatus to monitor charging information.
Call HP Support if it does not increase.
STATE 19
Charger Failed
SUGGESTED ACTION
Call HP Customer support
STATE 20
Not Present
SUGGESTED ACTION
Issue the CLI command, showbatterystatus. Check if BBU is present. If there, remove and
reinsert BBU to see if that will fix it.
If not there, call HP HP Support.
STATE 22
Open Circuit
SUGGESTED ACTION
Call HP Customer support
STATE 23
Output A Over Limit
SUGGESTED ACTION
Warning, charge too much. Battery state might become bad. Take a look to see if it needs replaced.
Issue the CLI command, showbatterystatus to monitor battery state. If the problem persist,
call HP Support.
STATE 24
Output V Over Limit
SUGGESTED ACTION
Warning, charge too much. Battery state might become bad. Take a look to see if it needs replaced.
Issue the CLI command, showbatterystatus to monitor battery state. If the problem persist,
call HP Support.
STATE 25
Output V Under Limit
225