HP 3PAR InForm OS 3.1.1 Messages and Operators Guide
MESSAGE CODE
0x0230003
TYPE
Port shutdown on fatal error
MESSAGE
Port <port_id> shut down: <time_shutdown>
SUGGESTED ACTION
Ensure the port settings are correct for the type of connection. For example, if the port is connected
to a fabric switch or hub, the port persona should be one of the fabric connection types
(7,8,9):controlport persona 7 n:s:p
NOTE: This will reset the port. If the port continues to generate firmware cores, it will shut down
again and the alert reposted.
1. Ensure the device connected on the port is functioning correctly. Perhaps by power-cycling
the device and issuing controlport rst n:s:p to reset the port and see if the new port
now functions correctly.
2. Verify that the problem is not port-specific by swapping the cable with a known working port.
3. If the problem persists, contact your local service provider.
231