HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

20 1:0:0 FC degraded disabled_B_port,servicing
21 1:0:1 FC degraded disabled_B_port,servicing
22 1:0:2 FC degraded disabled_B_port,servicing
23 1:0:3 FC degraded disabled_B_port,servicing
cli% showpd -p -cg 1
---Size(MB)---- ----Ports----
Id CagePos Type Speed(K) State Total Free A B
20 1:0:0 FC 10 degraded 139520 119808 0:0:2* 1:0:2-
21 1:0:1 FC 10 degraded 139520 122112 0:0:2* 1:0:2-
22 1:0:2 FC 10 degraded 139520 119552 0:0:2* 1:0:2-
23 1:0:3 FC 10 degraded 139520 122368 0:0:2* 1:0:2-
Cage Example 4
SComponent ---------Description--------- Qty
Cage Cages not on current firmware 1
Component -Identifier- ------Description------
Cage cage:3 Firmware is not current
Cage Suggested Action 4
Check the drive cage firmware revision using the command showcage and showcage -d
cageX. The showfirwaredb command indicates what the current firmware level should be for
the specific drive cage type.
NOTE: DC1 and DC3 cages have firmware in the FCAL modules; DC2 and DC4 cages have
firmware on the cage midplane. Theupgradecage command may be used to upgrade the firmware.
cli% showcage
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
2 cage2 2:0:3 0 3:0:3 0 24 29-43 2.37 2.37 DC2 n/a
3 cage3 2:0:4 0 3:0:4 0 32 29-41 2.36 2.36 DC2 n/a
cli% showcage -d cage3
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
3 cage3 2:0:4 0 3:0:4 0 32 29-41 2.36 2.36 DC2 n/a
-----------Cage detail info for cage3 ---------
.
.
.
-----------Midplane Info-----------
Firmware_status Old
Product_Rev 2.36
State Normal Op
Loop_Split 0
VendorId,ProductId 3PARdata,DC2
Unique_ID 10320300000AD100
cli% showfirmwaredb
Vendor Prod_rev Dev_Id Fw_status Cage_type Firmware_File
...
3PARDATA [2.37] DC2 Current DC2 /opt...dc2/lbod_fw.bin-2.37
Cage Example 5
Component -Identifier- ------------Description------------
Cage cage:4 Interface Card 0, SFP 0 is unqualified
Troubleshooting Storage System Components 297