HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

Cage Suggested Action 5
In this example, a 2Gb/sec SFP was installed in a 4Gb/sec drive cage (DC4), and the 2Gb SFP
is not qualified for use in this drive cage. For cage problems, the following CLI commands are
helpful: showcage -d, showcage -sfp, showcage -sfp -ddm, showcage -sfp -d, and
showpd -state.
cli% showcage -d cage4
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
4 cage4 2:2:1 0 3:2:1 0 8 30-37 2.37 2.37 DC4 n/a
-----------Cage detail info for cage4 ---------
Fibre Channel Info PortA0 PortB0 PortA1 PortB1
Link_Speed 2Gbps -- -- 4Gbps
----------------------------------SFP Info-----------------------------------
FCAL SFP -State- --Manufacturer-- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0 0 OK SIGMA-LINKS 2.1 No No No Yes
1 1 OK FINISAR CORP. 4.1 No No No Yes
Interface Board Info FCAL0 FCAL1
Link A RXLEDs Green Off
Link A TXLEDs Green Off
Link B RXLEDs Off Green
Link B TXLEDs Off Green
LED(Loop_Split) Off Off
LEDS(system,hotplug) Amber,Off Green,Off
...
cli% showcage -sfp -d cage4
--------Cage 4 FCAL 0 SFP 0--------
Cage ID : 4
Fcal ID : 0
SFP ID : 0
State : OK
Manufacturer : SIGMA-LINKS
Part Number : SL5114A-2208
Serial Number : U260651461
Revision : 1.4
MaxSpeed(Gbps) : 2.1
Qualified : No <<< Unqualified SFP
TX Disable : No
TX Fault : No
RX Loss : No
RX Power Low : No
DDM Support : Yes
--------Cage 4 FCAL 1 SFP 1--------
Cage ID : 4
Fcal ID : 1
SFP ID : 1
State : OK
Manufacturer : FINISAR CORP.
Part Number : FTLF8524P2BNV
Serial Number : PF52GRF
Revision : A
MaxSpeed(Gbps) : 4.1
Qualified : Yes
TX Disable : No
TX Fault : No
RX Loss : No
RX Power Low : No
298 Troubleshooting