HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

NOTE: These error counters cannot be cleared except by rebooting a controller node.
shownet -d
IP Address: 192.168.56.209 Netmask 255.255.255.0
Assigned to nodes: 0123
Connected through node 0
Status: Active
Admin interface on node 0
MAC Address: 00:02:AC:25:04:03
RX Packets: 1225109 TX Packets: 550205
RX Bytes: 1089073679 TX Bytes: 568149943
RX Errors: 0 TX Errors: 0
RX Dropped: 0 TX Dropped: 0
RX FIFO Errors: 0 TX FIFO Errors: 0
RX Frame Errors: 60 TX Collisions: 0
RX Multicast: 0 TX Carrier Errors: 0
RX Compressed: 0 TX Compressed: 0
Node
Displays node conditions that are not optimal.
Checks if node batteries have been tested in the last 30 days.
Checks for offline nodes.
Checks for power supply and battery problems.
Format of Possible Node Exception Messages
Node node:<nodeID> "Node is not online"
Node node:<nodeID> "Power supply <psID> detailed state is <status>
Node node:<nodeID> "Power supply <psID> AC state is <acStatus>"
Node node:<nodeID> "Power supply <psID> DC state is <dcStatus>
Node node:<nodeID> "Power supply <psID> battery is <batStatus>"
Node node:<priNodeID> "<bat> has not been tested within the last 30 days"
Suggested Node Action, General
For node error conditions, examine the node and node-component states with commands such as
shownode, shownode -s, shownode -d, showbattery, and showsys -d.
NOTE: For an F-Class system, the failure of a system fan is not detected except in the Alert section.
These fans cool the nodes in F-Class systems.
Node Example 1
Component -Identifier- ---------------Description----------------
Node node:0 Power supply 1 detailed state is DC Failed
Node node:0 Power supply 1 DC state is Failed
Node node:1 Power supply 0 detailed state is AC Failed
Node node:1 Power supply 0 AC state is Failed
Node node:1 Power supply 0 DC state is Failed
304 Troubleshooting