HP 3PAR InForm OS 3.1.1 Messages and Operators Guide

Voltage mV 3216 2900 3700 2700 3900
TX Bias mA 7 2 14 1 17
TX Power uW 335 79 631 67 631
RX Power uW 98 15 794 10 1259
cli% showcage
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model Side
0 cage0 0:0:1 0 1:0:1 0 15 33-38 08 08 DC3 n/a
1 cage1 --- 0 1:0:2 0 15 30-38 08 08 DC3 n/a
cli% showpd -s
Id CagePos Type -State-- -Detailed_State-
1 0:2:0 FC normal normal
...
13 1:1:0 NL degraded missing_A_port
14 1:2:0 FC degraded missing_A_port
cli% showpd -path
---------Paths---------
Id CagePos Type -State-- A B Order
1 0:2:0 FC normal 0:0:1 1:0:1 0/1
...
13 1:1:0 NL degraded 0:0:2\missing 1:0:2 1/-
14 1:2:0 FC degraded 0:0:2\missing 1:0:2 1/-
Port Example 2
Component -Description- Qty
Port Missing SFPs 1
Component -Identifier- -Description--
Port port:0:3:1 SFP is missing
Port Suggested Action 2
FC node-ports that normally contain SFPs will report an error if the SFP has been removed. The
condition can be checked using the showport -sfp command. In this example, the SFP in 0:3:1
has been removed from the adapter:
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
0:0:1 OK FINISAR_CORP. 2.1 No No No Yes
0:0:2 OK FINISAR_CORP. 2.1 No No No Yes
0:3:1 - - - - - - -
0:3:2 OK FINISAR_CORP. 2.1 No No No Yes
Port Example 3
Component -Description- Qty
Port Disabled SFPs 1
Component -Identifier- --Description--
Port port:3:5:1 SFP is disabled
312 Troubleshooting