HP 3PAR InForm OS 3.1.1 Messages and Operators Guide
Port Suggested Action 3
A node-port SFP will be disabled if the port has been placed offline using the controlport
offline command. Also see Example 4.
cli% showport -sfp
N:S:P -State- -Manufacturer- MaxSpeed(Gbps) TXDisable TXFault RXLoss DDM
3:5:1 OK FINISAR_CORP. 4.1 Yes No No Yes
3:5:2 OK FINISAR_CORP. 4.1 No No No Yes
Port Example 4
Component -Description- Qty
Port Offline ports 1
Component -Identifier- --Description--
Port port:3:5:1 is offline
Port Suggested Action 4
Check the state of the port with showport. If a port is offline, it was deliberately put in that state
using the controlport offline command. Offline ports may be restored using controlport
rst.
cli% showport
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type
3:5:1 target offline 2FF70002AC00054C 23510002AC00054C free
Port Example 5
Component ------------Description------------ Qty
Port Ports with mismatched mode and type 1
Component -Identifier- ------Description-------
Port port:2:0:3 Mismatched mode and type
Port Suggested Action 5
This output indicates that the port's mode, such as an initiator or target, is not correct for the
connection type, such as disk, host, iscsi or rcfc. Useful CLI commands are showport, showport
-c, showport -par, showport -rcfc, showcage, etc.
cli% showport
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type
2:0:1 initiator ready 2FF70002AC000591 22010002AC000591 disk
2:0:2 initiator ready 2FF70002AC000591 22020002AC000591 disk
2:0:3 target ready 2FF70002AC000591 22030002AC000591 disk
2:0:4 target loss_sync 2FF70002AC000591 22040002AC000591 free
NOTE: A known problem exists when Remote Copy is configured on a Fibre Channel adapter
port. These ports will be flagged in error and these errors can be ignored. This will be fixed in a
future release.
Component -Identifier- ------Description-------
Port port:0:1:1 Mismatched mode and type
Troubleshooting Storage System Components 313