HP 3PAR InForm OS 3.1.1 Messages and Operators Guide
cli% showport
N:S:P Mode State ----Node_WWN---- -Port_WWN/HW_Addr- Type
0:1:1 initiator ready 2FF70002AC000190 20110002AC000190 rcfc
0:1:2 initiator loss_sync 2FF70002AC000190 20120002AC000190 free
0:1:3 initiator loss_sync 2FF70002AC000190 20130002AC000190 free
0:1:4 initiator loss_sync 2FF70002AC000190 20140002AC000190 free
RC
Displays Remote Copy issues.
• Checks Remote Copy targets
• Checks Remote Copy links
• Checks Remote Copy Groups and VVs
Format of Possible RC Exception Messages
RC rc:<name> "All links for target <name> are down but target not yet marked failed."
RC rc:<name> "Target <name> has failed."
RC rc:<name> "Link <name> of target <target> is down."
RC rc:<name> "Group <name> is not started to target <target>."
RC rc:<vvname> "VV <vvname> of group <name> is stale on target <target>."
RC rc:<vvname> "VV <vvname> of group <name> is not synced on target <target>."
RC Example
Component -Description- Qty
RC Stale volumes 1
Component --Identifier--- ---------Description---------------
RC rc:yush_tpvv.rc VV yush_tpvv.rc of group yush_group.r1127
is stale on target S400_Async_Primary.
RC Suggested Action
Perform remote copy troubleshooting such as checking the physical links between the storage
system, and using CLI commands such as showrcopy, showrcopy -d, showport -rcip,
showport -rcfc, shownet -d, controlport rcip ping, etc.
SNMP
Displays issues with SNMP. Attempts the showsnmpmgr command and reports errors if the CLI
returns an error.
Format of Possible SNMP Exception Messages
SNMP -- <err>
SNMP Example
Component -Identifier- ----------Description---------------
SNMP -- Could not obtain snmp agent handle. Could be
misconfigured.
314 Troubleshooting