Table 22 Drive Chassis OPs Panel LED Displays (continued)
IndicatesAppearanceLED
• Indicates test state (5 seconds), if:
◦ Power On LED is steady green.
◦ Power Supply/Cooling/Temperature Fault LED is steady
amber.
◦ System Fault LED is steady amber.
◦ 2GB Link Speed LED is steady amber.
Steady amber lightInvalid Address LED
Invalid address mode ID switch setting if Power On LED is steady
green.
Flashing amber light
Steady amber lightSystem Fault LED
• Test state (5 seconds), if:
Power On LED is steady green.◦
◦ Power Supply/Cooling/Temperature Fault LED is steady
amber.
◦ Invalid Address LED is steady amber.
◦ 2GB Link Speed LED is steady amber.
• Processor module in FC-AL failure, if:
◦ Power ON LED is steady green.
◦ Power Supply/Cooling/Temperature Fault LED is off.
• Unknown FC-AL module type installed, I2C Bus failure, or
backplane autostart watchdog failure, if:
◦ Power ON LED is steady green.
◦ Power Supply/Cooling/Temperature Fault LED is off.
• Ops to ESI communication failure, if:
◦ Power ON LED is steady green.
◦ Power Supply/Cooling/Temperature Fault LED is flashing.
Flashing amber light
• Over or under temperature, if:
Power On LED is steady green.◦
◦ Power Supply/Cooling/Temperature Fault LED is steady
amber.
• Power supply is removed if:
Power On LED is steady green.◦
◦ Power Supply/Cooling/Temperature Fault LED is flashing.
• No drives fitted, if:
◦ Power ON LED is steady green.
◦ Power Supply/Cooling/Temperature Fault LED is off.
62 Understanding F-Class Storage System LED Status