HP 3PAR InForm OS 3.1.1 Messages and Operators Guide
MESSAGE CODE
0x0010001
TYPE
Serial link event
MESSAGE 1
Serial link from node x to node y failed. FIFO is full.
SUGGESTED ACTION
The serial link hardware between node x and y has detected an error. If the problem is persistent,
or if other node-related errors are present, Node x should be diagnosed and replaced. If there is
a hardware failure in the main link connecting nodes x and y at the same time there is a serial
link failure, there is a 50% chance of losing the healthy node.
MESSAGE 2
Serial link from node x to node y failed. Rate of loss 100%.
SUGGESTED ACTION
The serial link hardware between node x and node y has detected an error. Node y should be
replaced and diagnosed. If there is a hardware failure in the main link connecting nodes x and y
at the same time there is a serial link failure, there is a 50% chance of losing the healthy node.
MESSAGE 3
Serial link from node x to node y failed. Rate of loss <percent_of_loss>.
SUGGESTED ACTION
There might be an error in the low-level software controlling the serial port in either node x or node
y; or the hardware might be unstable. If there is a hardware failure in the main link connecting
nodes x and y at the same time there is a serial link failure, there is a 50% chance of losing the
healthy node. If there are many nodes that report the same condition to a specific node, replace
and diagnose that node.
94 Alerts